Introducing Enerdrive | Dometic’s eSYSTEM pre-wired board power system range for 4WD Canopies, Caravans, Camper Trailers, Commercial Work Vehicles and more. Enerdrive | Dometic have created many different layouts to fit nearly every possible application. Designed for the DIY handyman with basic electrical knowledge through to the professional looking to save installation time.

$7,388.00$8,405.00

SKU: eSYS-COMBI-EP-01, eSYS-COMBI-SI-01, eSYS-COMBI-SI-02 Category:

Introducing Enerdrive | Dometic’s eSYSTEM pre-wired board power system range for 4WD Canopies, Caravans, Camper Trailers, Commercial Work Vehicles and more. Enerdrive | Dometic have created many different layouts to fit nearly every possible application. Designed for the DIY handyman with basic electrical knowledge through to the professional looking to save installation time.

eSYS-COMBI-SI-01

  • 535W x 1195H x 147Dmm
  • Charge via a Vehicle input, Solar or Mains power;
    • Vehicle: 12 or 24v input, up to 100A Charging
    • Solar:
      • (DC2DC): up to 45VOC / 800W
      • (Dual MPPT): up to 100VOC / 1800W
    • Mains 240V: 120A Charging
  • Inverter suitable for appliances that use up to 3000W of power for operation, with a peak surge of 5000W, such as induction cooktops, rooftop air-conditioning units and more
  • Your choice of ePRO+ Battery Monitor and Simarine Battery Monitor
  • 2nd DC2DC Charger available as optional extra

eSYS-COMBI-SI-02 (24V)

  • 535W x 1195H x 147Dmm
  • Charge via a Vehicle input, Solar or Mains power;
    • Vehicle: 12 or 24v input, up to 60A Charging at 24V
    • Solar:
      • (DC2DC 24V 30A): up to 45VOC / 800W
      • (Dual MPPT): up to 100VOC / 1800W
    • Mains 240V: 70A Charging at 24V
  • Your choice of ePRO+ Battery Monitor and Simarine Battery Monitor
  • Inverter suitable for appliances that use up to 3500W of power for operation, with a peak surge of 6500W, such as induction cooktops, rooftop air-conditioning units and more
  • 2nd DC2DC Charger available as optional extra

Additional information

SKU

eSYS-COMBI-EP-01, eSYS-COMBI-SI-01, eSYS-COMBI-SI-02

Features

eSYS-COMBI-SI-01

  • 535W x 1195H x 147Dmm
  • Charge via a Vehicle input, Solar or Mains power;
    • Vehicle: 12 or 24v input, up to 100A Charging
    • Solar:
      • (DC2DC): up to 45VOC / 800W
      • (Dual MPPT): up to 100VOC / 1800W
    • Mains 240V: 120A Charging
  • Inverter suitable for appliances that use up to 3000W of power for operation, with a peak surge of 5000W, such as induction cooktops, rooftop air-conditioning units and more
  • Your choice of ePRO+ Battery Monitor and Simarine Battery Monitor
  • 2nd DC2DC Charger available as optional extra

eSYS-COMBI-SI-02 (24V)

  • 535W x 1195H x 147Dmm
  • Charge via a Vehicle input, Solar or Mains power;
    • Vehicle: 12 or 24v input, up to 60A Charging at 24V
    • Solar:
      • (DC2DC 24V 30A): up to 45VOC / 800W
      • (Dual MPPT): up to 100VOC / 1800W
    • Mains 240V: 70A Charging at 24V
  • Your choice of ePRO+ Battery Monitor and Simarine Battery Monitor
  • Inverter suitable for appliances that use up to 3500W of power for operation, with a peak surge of 6500W, such as induction cooktops, rooftop air-conditioning units and more
  • 2nd DC2DC Charger available as optional extra

Specifications

Pre-Wired Board Power Systems Comparison

SKU / Items IncludedDC2DC Battery Charger (Vehicle/Solar)AC 230v Battery ChargerAC Transfer InverterInverter/Charger Combination UnitSolar ControllerePRO+ 500A Battery Monitor with Remote DisplaySimarine Pico LCD WIFI Monitoring ScreenSimarine SC303 300A Main Battery ShuntSimarine SCQ25T Individual Load/Charge ModuleSimarine SCQ50 Individual Load/Charge ModuleSimarine ST107 Tank Monitoring ModuleLow Battery CutoutMain Load Distribution Fuse Block (Low Battery Protected)24hr Critical Load Distribution Fuse BlockBattery Restart Switch (Lithium Batteries)Inverter Circuit Breaker (Pre Wired Inverter Supply)Inverter/Charger Fuse Holder (Pre Wired Inverter/Charger Supply)Solar Input Circuit BreakerDimensions (mm)WarrantySpecial Notes
ESYS-CEN3DC40+EN31240EN1120S-XEN55050EN-LBC1224-60EA-START-BUTTONEN-RCB2001185W x 380H x 125Dmm5 Years
ESYS-DEN3DC40+EN31240SI-PICO-3SI-SC303SI-SCQ25TEN-LBC1224-60EA-FB-07EA-FB-10EA-START-BUTTONEN-RCB200EN-RCB40490W x 600H x 100Dmm5 Years
ESYS-EEN3DC40+EN31240EN55050EN-LBC1224-60EA-FB-07EA-FB-10EA-START-BUTTONEN-RCB200EN-RCB40490W x 600H x 100Dmm5 Years
ESYS-FEN3DC40+EN31240EN1120S-XSI-PICO-3SI-SC303SI-SCQ25TEN-LBC1224-60EA-FB-11EA-START-BUTTONEN-RCB200EN-RCB401185W x 380H x 125Dmm5 Years
ESYS-GEN3DC40+EN31240SI-PICO-3SI-SC303SI-SCQ25TEN-LBC1224-60EA-FB-11EA-START-BUTTONEN-RCB200EN-RCB40790W x 380H x 100Dmm5 Years
ESYS-HEN3DC40+EN31260SR-TS-45-EDEN55050EN-LBC1224-60EA-FB-08EN-RCB200EN-RCB601195W x 380H x 111Dmm5 Years
ESYS-IEN3DC40+EN31260SR-TS-45-EDSI-PICO-3SI-SC303SI-SCQ50EN-LBC1224-60EA-FB-08EN-RCB200EN-RCB601195W x 380H x 111Dmm5 Years
ESYS-JEN3DC40+EN31260SR-TS-45-EDEN55050EN-LBC1224-60EN-RCB200EN-RCB60920W x 380H x 111Dmm5 Years
ESYS-KEN3DC40+EN31240SR-TS-45-EDSI-PICO-3SI-SC303SI-SCQ25TEA-FB-10EA-START-BUTTONEN-RCB200EN-RCB60490W x 600H x 100Dmm5 Years
ESYS-LEN3DC40+EN31240SR-TS-45-EDEN55050EA-FB-10EA-START-BUTTONEN-RCB200EN-RCB60490W x 600H x 100Dmm5 Years
ESYS-M-EP-03EN3DC40+EN31240EN55050EN-LBC1224-60600W x 350H x 100Dmm5 Years
ESYS-M-SI-03EN3DC40+EN31240SI-PICO-3SI-SC303EN-LBC1224-60600W x 350H x 100Dmm5 Years
ESYS-N-EP-01EN3DC40+EN43540 x 2EN55050EN-LBC1224-60EA-FB-08400A T-ClassEN-RCB50 x 2 / EN-RCB40 x 11190W x 380H x 100Dmm5 YearsSuits Inverter/Charger
ESYS-N-SI-01EN3DC40+EN43540 x 2SI-PICO-3SI-SC303SI-SCQ50EN-LBC1224-60EA-FB-08400A T-ClassEN-RCB50 x 2 / EN-RCB40 x 11190W x 380H x 100Dmm5 YearsSuits Inverter/Charger
ESYS-OEN3DC40+EN43540 x 2SI-PICO-3SI-SC303SI-SCQ50EA-FB-10EN-RCB50 x 2520W x 600H x 85Dmm5 YearsSuits Inverter/Charger
ESYS-R-EP-01EN3DC40+EN31240EN1120S-XEN43540EN55050EN-RCB200EN-RCB50535W x 1195H x 125Dmm5 Years
ESYS-R-SI-01EN3DC40+EN31240EN1120S-XEN43540SI-PICO-3SI-SC303SI-SCQ50SI-ST107EN-RCB200EN-RCB50535W x 1195H x 125Dmm5 Years
ESYS-R-EP-02EN3DC40+EN31260EN1226S-XEN43540 x 2EN55050EN-RCB250EN-RCB50 x 2535W x 1195H x 125Dmm5 Years
ESYS-R-SI-02EN3DC40+EN31260EN1226S-XEN43540 x 2SI-PICO-3SI-SC303SI-SCQ50SI-ST107EN-RCB250EN-RCB50 x 2535W x 1195H x 125Dmm5 Years
ESYS-R-EP-03EN3DC40+EN312100EN1226S-XEN43540 x 2EN55050EN-RCB250EN-RCB50 x 2535W x 1195H x 125Dmm5 Years
ESYS-R-SI-03EN3DC40+EN312100EN1226S-XEN43540 x 2SI-PICO-3SI-SC303SI-SCQ50SI-ST107EN-RCB250EN-RCB50 x 2535W x 1195H x 125Dmm5 Years
ESYS-S-EP-02EN3DC40+EN31260EN1226S-XEN43540 x 2EN55050EN-LBC1224-60EN-RCB250EN-RCB50 x 2550W x 1195H x 125Dmm5 YearsIncludes Solar Input Fuses
ESYS-S-SI-02EN3DC40+EN31260EN1226S-XEN43540 x 2SI-PICO-3SI-SC303SI-SCQ50SI-ST107EN-LBC1224-60EN-RCB250EN-RCB50 x 2550W x 1195H x 125Dmm5 YearsIncludes Solar Input Fuses
ESYS-UEN3DC40+EN31240SI-SCC8/SPDU-52SI-SC303SI-SCQ50EN-RCB200EN-RCB40800W x 380H x 100Dmm5 YearsSimarine Digital Switching
ESYS-COMBI-EP-01EN3DC40+EPC-3000-12EN43540 x 2EN55050EN-RCB50 x 2535W x 1195H x 147Dmm5 YearsIncludes URC for Combi (5095500)
ESYS-COMBI-SI-01EN3DC40+EPC-3000-12EN43540 x 2SI-PICO-3SI-SC303SI-SCQ50SI-ST107EN-RCB50 x 2535W x 1195H x 147Dmm5 YearsIncludes URC for Combi (5095500)
ESYS-COMBI-SI-02EN3DC30-24 x 2EPC-3500-24EN43540 x 2SI-PICO-3SI-SC303SI-SCQ50SI-ST107EN-RCB50 x 2535W x 1195H x 147Dmm5 YearsIncludes URC for Combi (5095500)
ESYS-ICA-EP-02EN3DC40+EN230100-12EN43540 x 2EN55050400A T-ClassEN-RCB50 x 2535W x 1195H x 120Dmm5 YearsIncludes Battery Isolation Switch (BS-6006B)
ESYS-ICA-SI-02EN3DC40+EN230100-12EN43540 x 2SI-PICO-3SI-SC303SI-SCQ50SI-ST107400A T-ClassEN-RCB50 x 2535W x 1195H x 120Dmm5 YearsIncludes Battery Isolation Switch (BS-6006B)
ESYS-ICB-EP-01EN3DC40+EN220080-12EN55050EA-FB-11EN-RCB250EN-RCB401020W x 350H x 120Dmm5 Years
ESYS-ICC-SI-01EN3DC40+EN230100-12SI-SCC8/SPDU-52SI-SC303SI-SCQ50400A T-Class715W x 605H x 120Dmm5 YearsSimarine Digital Switching
EPDM-01300W x 200H x 78Dmm5 Years
EPDM-02EN55050EA-FB-11EN-RCB250200W x 460H x 78Dmm5 Years
EPDM-03SI-PICO-3SI-SC303SI-SCQ50EN-RCB250290W x 435H x 78Dmm5 Years
RV60 & RV80 RANGE - SPECIFICATIONS
Items IncludedAC 20Amp 230v Battery ChargerAC 40Amp 230v Battery ChargerDC2DC 40A+ Battery Charger (Vehicle/Solar)ePRO+ 500A Battery Monitor with Remote Display, with Audible & Visual AlarmePOWER AC Charger 30A Output Fuse ConnectionePOWER AC Charger 50A Output Fuse ConnectionePOWER DC2DC 60A Output Fuse Connection50A Load Output Fuse Connection8 Circuit "Wedge" Fuse BlockLow Battery Cutout
(Programmed in ePRO+ via Users Data Input)
12mm Black Plastic Mounting Board. Water & Rot Resistance
K-RV-60******480L x 400W x 100Dmm5 Years
K-RV-60-01*******480L x 400W x 100Dmm5 Years
K-RV-60-02********480L x 400W x 100Dmm5 Years
K-RV-60-03********480L x 400W x 100Dmm5 Years
K-RV-80******480L x 400W x 100Dmm5 Years
K-RV-80-01*******480L x 400W x 100Dmm5 Years
K-RV-80-02********480L x 400W x 100Dmm5 Years
K-RV-80-03********480L x 400W x 100Dmm5 Years
(*) Indicates Standard Fitment