Lifetime of Unrivalled Australian Technical Support

ESYS-PDM

Enerdrive | Dometic Power Distribution Module

Optional Battery Monitor:

  • Enerdrive | Dometic ePRO+ Battery Monitor – EN55050
  • Simarine Pico+ Display Panel Mount Black – SI-PICO-3 with SI-SC303 & SI-SCQ50

The Enerdrive | Dometic Power Distribution Module is a DIY-friendly solution for managing all of your electrical loads in a single, central location. It features a main positive input with circuit breakers to protect your inverter (model dependent) and system loads, as well as midi and blade fuse holders for additional loads. A bus bar is also included for all of your negative connections.

The Power Distribution Module is available in three versions:

With ePRO+ Battery Monitor:

  • Includes the ePRO+ Battery Monitor, which provides real-time information on your battery voltage, current, and state of charge.
  • 2 circuit breakers: one for system and one for inverter loads up to 2600W
  • 6 Midi Fuse Holders – For charging inputs and load dist
  • Small load circuit for lighting etc
  • 3 position negative bus bar for all negative connections

With Simarine Battery Monitor:

  • Includes the more advanced Simarine Battery Monitor
  • 6 Midi Fuse Holders – For charging inputs and load dist
  • 2 circuit breakers: one for system and one for inverter loads up to 2600W
  • The simarine SCQ0 module – Can monitor individual loads up to 50A per circuit!

Without Battery Monitor:

  • This model does not include a battery monitor
  • 1 x 120A system load
  • 3 Mide fuses
  • A dual position common negative bus bar

No matter which model you choose, the Enerdrive Power Distribution Module is a great way to keep your electrical system organised and protected.

Benefits:

  • Centralised power distribution
  • Overload protection
  • Easy installation
  • DIY-friendly

Applications:

  • RVs
  • Campers
  • Boats
  • Off-grid systems
  • Solar power systems
  • Any other application where multiple electrical loads need to be managed
SKU: ESYS-PDM-01, ESYS-PDM-02, ESYS-PDM-03 Category:

Introducing Enerdrive | Dometic’s eSYSTEM pre-wired board power system range for 4WD Canopies, Caravans, Camper Trailers, Commercial Work Vehicles and more. Enerdrive | Dometic have created many different layouts to fit nearly every possible application. Designed for the DIY handyman with basic electrical knowledge through to the professional looking to save installation time.

ESYS-PDM-01

  • Distribution panel ideal for smaller systems without an inverter.
  • Main distribution resettable circuit breaker 120A
  • 4 x Midi fuses for Loads / Chargers with main bus bar connected to distribution circuit breaker
  • 500A Main negative busbar

ESYS-PDM-02

  • Distribution panel ideal for smaller systems with inverters
  • Main distribution resettable circuit breaker 120A
  • Inverter Circuit breaker 200A standard optional 250A for 2600W inverters
  • 4 x Midi fuses for Loads / Chargers with main bus bar connected to distribution circuit breaker
  • 500A Main negative busbar
  • ePRO+ battery monitor for system monitoring and State of Charge tracking
  • 4 position 100A fuse block for 24 hour loads

ESYS-PDM-03

  • Distribution panel ideal for smaller systems with inverters
  • Main distribution resettable circuit breaker 120A
  • Inverter Circuit breaker 200A standard optional 250A for 2600W inverters
  • 4 x Midi fuses for Loads / Chargers with main bus bar connected to distribution circuit breaker
  • 500A Main negative busbar
  • Simarine SC303 main shunt for system monitoring and state of charge tracking
  • Simarine SCQ50 quad shunt for individual load and charge monitoring
  • Simarine Pico 3 panel mount black display

Features

Introducing Enerdrive | Dometic’s eSYSTEM pre-wired board power system range for 4WD Canopies, Caravans, Camper Trailers, Commercial Work Vehicles and more. Enerdrive | Dometic have created many different layouts to fit nearly every possible application. Designed for the DIY handyman with basic electrical knowledge through to the professional looking to save installation time.

ESYS-PDM-01

  • Distribution panel ideal for smaller systems without an inverter.
  • Main distribution resettable circuit breaker 120A
  • 4 x Midi fuses for Loads / Chargers with main bus bar connected to distribution circuit breaker
  • 500A Main negative busbar

ESYS-PDM-02

  • Distribution panel ideal for smaller systems with inverters
  • Main distribution resettable circuit breaker 120A
  • Inverter Circuit breaker 200A standard optional 250A for 2600W inverters
  • 4 x Midi fuses for Loads / Chargers with main bus bar connected to distribution circuit breaker
  • 500A Main negative busbar
  • ePRO+ battery monitor for system monitoring and State of Charge tracking
  • 4 position 100A fuse block for 24 hour loads

ESYS-PDM-03

  • Distribution panel ideal for smaller systems with inverters
  • Main distribution resettable circuit breaker 120A
  • Inverter Circuit breaker 200A standard optional 250A for 2600W inverters
  • 4 x Midi fuses for Loads / Chargers with main bus bar connected to distribution circuit breaker
  • 500A Main negative busbar
  • Simarine SC303 main shunt for system monitoring and state of charge tracking
  • Simarine SCQ50 quad shunt for individual load and charge monitoring
  • Simarine Pico 3 panel mount black display

Specifications