ePDM
Enerdrive | Dometic Power Distribution Module
The Enerdrive | Dometic Power Distribution Module is a DIY-friendly solution for managing all of your electrical loads in a single, central location. It features a main positive input with circuit breakers to protect your inverter (model dependent) and system loads, as well as midi and blade fuse holders for additional loads. A bus bar is also included for all of your negative connections. The Power Distribution Module is available in three versions: With ePRO+ Battery Monitor, With Simarine Battery Monitor and Without Battery Monitor.
$438.00 – $1,838.00
Introducing Enerdrive | Dometic’s eSYSTEM pre-wired board power system range for 4WD Canopies, Caravans, Camper Trailers, Commercial Work Vehicles and more. Enerdrive | Dometic have created many different layouts to fit nearly every possible application. Designed for the DIY handyman with basic electrical knowledge through to the professional looking to save installation time.
Additional information
Battery Monitor | No Battery Monitor, ePRO+, Simarine |
---|
Features
Introducing Enerdrive | Dometic’s eSYSTEM pre-wired board power system range for 4WD Canopies, Caravans, Camper Trailers, Commercial Work Vehicles and more. Enerdrive | Dometic have created many different layouts to fit nearly every possible application. Designed for the DIY handyman with basic electrical knowledge through to the professional looking to save installation time.
EPDM-01
- Distribution panel ideal for smaller systems without an inverter.
- Main distribution resettable circuit breaker 120A
- 4 x Midi fuses for Loads / Chargers with main bus bar connected to distribution circuit breaker
- 500A Main negative busbar
EPDM-02
- Distribution panel ideal for smaller systems with inverters
- Main distribution resettable circuit breaker 120A
- Inverter Circuit breaker 200A standard optional 250A for 2600W inverters
- 4 x Midi fuses for Loads / Chargers with main bus bar connected to distribution circuit breaker
- 500A Main negative busbar
- ePRO+ battery monitor for system monitoring and State of Charge tracking
- 4 position 100A fuse block for 24 hour loads
EPDM-03
- Distribution panel ideal for smaller systems with inverters
- Main distribution resettable circuit breaker 120A
- Inverter Circuit breaker 200A standard optional 250A for 2600W inverters
- 4 x Midi fuses for Loads / Chargers with main bus bar connected to distribution circuit breaker
- 500A Main negative busbar
- Simarine SC303 main shunt for system monitoring and state of charge tracking
- Simarine SCQ50 quad shunt for individual load and charge monitoring
- Simarine Pico 3 panel mount black display
Specifications
Pre-Wired Board Power Systems Comparison
ePDM | eSYS-C | eSYS-D | eSYS-E | eSYS-F | eSYS-G | eSYS-H | eSYS-I | eSYS-J | eSYS-K | eSYS-L | eSYS-M | eSYS-N | eSYS-O | eSYS-R | eSYS-COMBI | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SKU | ePDM-01, ePDM-02, ePDM-03 | eSYS-C | eSYS-D | eSYS-E | eSYS-F | eSYS-G | eSYS-H | eSYS-I | eSYS-J | eSYS-K | eSYS-L | eSYS-M | eSYS-N-EP-01, eSYS-N-SI-01 | eSYS-O | eSYS-R-EP-01, eSYS-R-SI-01, eSYS-R-EP-02, eSYS-R-EP-02, eSYS-R-SI-02, eSYS-R-EP-03, eSYS-R-SI-03 | eSYS-COMBI-EP-01, eSYS-COMBI-SI-01, eSYS-COMBI-EP-02, eSYS-COMBI-SI-02 |
AC 40Amp 230v Battery Charger | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | eSYS-R-EP-01, eSYS-R-SI-01 | |||||||
AC 60Amp 230v Battery Charger | ✓ | ✓ | ✓ | eSYS-R-EP-02, eSYS-R-SI-02 | ||||||||||||
AC 100Amp 230v Battery Charger | eSYS-R-EP-03, eSYS-R-SI-03 | eSYS-COMBI-EP-01, eSYS-COMBI-SI-01, eSYS-COMBI-EP-02, eSYS-COMBI-SI-02 | ||||||||||||||
DC2DC 40A+ Battery Charger (Vehicle/Solar) | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | eSYS-N-EP-01, eSYS-N-SI-01 | ✓ | eSYS-R-EP-01, eSYS-R-SI-01, eSYS-R-EP-02, eSYS-R-SI-02, eSYS-R-EP-03, eSYS-R-SI-03 | eSYS-COMBI-EP-01, eSYS-COMBI-SI-01 | |
DC2DC 30Amp 24V Battery Charger (Vehicle/Solar) | ||||||||||||||||
Morningstar Tristar PWM-45A Solar Controller | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | eSYS-R-EP-02, eSYS-R-SI-02, eSYS-R-EP-03, eSYS-R-SI-03 | eSYS-COMBI-EP-01, eSYS-COMBI-SI-01, eSYS-COMBI-EP-02, eSYS-COMBI-SI-02 | ||||||||
Enerdrive ePOWER MPPT 40A Solar Controller | ✓ | ✓ | ✓ | ✓ | eSYS-N-SI-01 | ✓ | eSYS-R-EP-02, eSYS-R-SI-02, eSYS-R-EP-03, eSYS-R-SI-03 | eSYS-COMBI-EP-01, eSYS-COMBI-SI-01 | ||||||||
ePRO+ 500A Battery Monitor with Remote Display | ePDM-02 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | eSYS-N-EP-01 | eSYS-R-EP-01, eSYS-R-SI-01 | eSYS-COMBI-EP-02, eSYS-COMBI-SI-02 | ||||||
Simarine Pico LCD WiFi Monitoring Screen | ePDM-03 | ✓ | ✓ | ✓ | ✓ | ✓ | eSYS-N-SI-01 | ✓ | eSYS-R-EP-02, eSYS-R-SI-02, eSYS-R-EP-03, eSYS-R-SI-03 | eSYS-COMBI-EP-01, eSYS-COMBI-SI-01 | ||||||
Simarine SC303 300A Main Battery Shunt | ePDM-03 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | eSYS-R-SI-02, eSYS-R-EP-03, eSYS-R-SI-03 | eSYS-COMBI-EP-01, eSYS-COMBI-SI-01 | |||||||
Simarine SCQ25T Individual Load/Charge Module | ✓ | ✓ | ✓ | ✓ | eSYS-N-SI-01 | ✓ | eSYS-R-SI-01 | |||||||||
Simarine SCQ50 Individual Load/Charge Module | ePDM-03 | ✓ | ✓ | eSYS-R-EP-02, eSYS-R-SI-02, eSYS-R-EP-03, eSYS-R-SI-03 | eSYS-COMBI-EP-01, eSYS-COMBI-SI-01, eSYS-COMBI-EP-02, eSYS-COMBI-SI-02 | |||||||||||
Simarine ST107 Tank Monitoring Module | ||||||||||||||||
Inverter Breaker 200A (Pre-wired Inverter Supply) | ePDM-02, ePDM-03 | ✓ | ✓ | ✓ | eSYS-N-EP-01, eSYS-N-SI-01 | |||||||||||
Battery Restart Switch (Lithium Batteries) | ✓ | ✓ | ✓ | ✓ | ✓ | |||||||||||
24hr Critical Load Distribution Fuse Block | ePDM-02 | ✓ | ✓ | ✓ | eSYS-N-SI-01 | eSYS-R-EP-01, eSYS-R-SI-01, eSYS-R-EP-02, eSYS-R-EP-02, eSYS-R-SI-02, eSYS-R-EP-03, eSYS-R-SI-03 | eSYS-COMBI-EP-01, eSYS-COMBI-SI-01, eSYS-COMBI-EP-02, eSYS-COMBI-SI-02 | |||||||||
Main Distribution Circuit Breaker 120A | ePDM-01, ePDM-02, ePDM-03 | |||||||||||||||
Main Negative Busbar 500A | ePDM-01, ePDM-02, ePDM-03 | |||||||||||||||
Main Load Distribution Fuse Block | ePDM-01, ePDM-02, ePDM-03 | eSYS-N-EP-01 | ✓ | |||||||||||||
2000W AC Transfer Inverter | ✓ | ✓ | ✓ | eSYS-N-SI-01 | eSYS-R-EP-01, eSYS-R-SI-01, eSYS-R-EP-02, eSYS-R-EP-02, eSYS-R-SI-02, eSYS-R-EP-03, eSYS-R-SI-03 | eSYS-COMBI-EP-01, eSYS-COMBI-SI-01, eSYS-COMBI-EP-02, eSYS-COMBI-SI-02 | ||||||||||
2600W AC Transfer Inverter | ✓ | eSYS-N-EP-01 | ||||||||||||||
Dimensions | ePDM-01: 200W x 300Hmm / ePDM-02: 200W x 460Hmm / ePDM-03: 290W x 435Hmm | 1185W x 380H x 130Dmm | 600W x 490H x 100Dmm | 600W x 490H x 100Dmm | 1185W x 380H x 130Dmm | 790W x 380H x 100Dmm | 1195W x 380H x 111Dmm | 1195W x 380H x 111Dmm | 920W x 380H x 111Dmm | 490W x 600 H x 111D mm | 490W x 600 H x 111D mm | 600W x 350H x 111D mm | 1190W x 380H x 111D mm | 600H x 520W x 111Dmm | 535W x 1195H x 111D mm | 535W x 1195H x 147D mm |
Warranty | 5 Years | 5 Years | 5 Years | 5 Years | 5 Years | 5 Years | 5 Years | 5 Years | 5 Years | 5 Years | 5 Years | 5 Years | 5 Years | 5 Years | 5 Years | 5 Years |
(✓) or (SKU) Indicates Standard Fitment |
Downloads
Download Wiring DiagramYou must be logged in to post a review.
Reviews